  smartpro 230v 1000va 900w line-interactive sine wave ups, snmp, webcard, 2u rack/tower, usb, db9 serial model number: SMX1000RT2U description tripp lite smartpro line interactive ups with enhanced lcd interface offers network-grade power protection for critical server, network and telecommunications equipment. line interactive uninterruptible power supply (ups) with built-in auto-voltage regulation (avr) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. interactive lcd interface reports ups operating mode, detailed ups and site-power data, plus enables a variety of ups setup and configuration options. super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 97% line-mode efficiency offers reduced heat emissions and operating costs. network management interfaces support communications via usb, rs-232 and optional snmpwebcard network interface. hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x. network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. includes poweralert monitoring software and complete cabling. switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. emergency power off (epo) interface. lcd display panel easily rotates for viewing in rackmount or tower configurations. audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. programmable self-test. field-replaceable, hot-swappable batteries. features tripp lite SMX1000RT2U line-interactive 2u rack/tower ups with 1000va / 1kva capacity line interactive ups with automatic voltage regulation (avr) corrects brownouts and overvoltages from 182 to 278v c14 ac power inlet; 6 c13 output receptacles, two independently switchable output load banks maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages high 97% efficiency rating in line-power mode offers reduced power consumption and btu emissions internal batteries offer 11.9 minutes at 50% load (450w) and 3.6 minutes at 100% load (900w) hot-swappable, user-replaceable internal batteries can be replaced with no disruption to connected equipment front panel lcd monitoring screen with mode and enter buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed ups and site power information lcd interface also supports a number of advanced user setup and operating preferences highlights 1kva / 1000va / 900w line-interactive 2u rack/tower ups, sine wave 230v output, corrects brownouts and overvoltages from 182v to 278v 0.9 power factor, interactive lcd interface 4-post compatible mounting accessories 97% line-mode efficiency; 2 switched load banks usb, rs232, epo and slot for snmpwebcard option 230v c14 inlet, 6 c13 outlets package includes SMX1000RT2U ups system poweralert software with usb, serial & epo cabling 4-post rackmount installation kit set of 2 c13/c14 power cables instruction manual 1 / 5
ships with 4 post rackmount installation hardware; optional 2postrmkitwm enables 2 post rackmount/wallmount installation; optional 2-9ustand enables tower placement built-in usb, rs-232 and optional snmpwebcard accessory monitoring options hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x included poweralert ups monitoring software; built-in emergency power off (epo) interface with cable specifications output output volt amp capacity (va) 1000 output kva capacity (kva) 1 output watt capacity (watts) 900 output kw capacity (kw) 0.9 power factor 0.9 nominal output voltage(s) supported 220v; 230v; 240v nominal voltage details 230v nominal inverter output voltage frequency compatibility 50 / 60 hz output voltage regulation (line mode) +6%, -11% output voltage regulation (battery mode) +/- 5% output receptacles (6) c13 included output power cables includes 2 c13 to c14 output power cables load management receptacles two switchable two-outlet c13 load banks hot-swap pdu options pdubhv10 (2u / 8 c13 outlets) output ac waveform (ac mode) sine wave output ac waveform (battery mode) pure sine wave input rated input current (maximum load) 4.8a nominal input voltage(s) supported 230v ac ups input connection type c14 inlet ups input connection description iec320-c14 input connection accepts a variety of user supplied detachable c13 output cordsets to match country or site-specific power sources input circuit breakers 10a input phase single-phase 2 / 5
battery full load runtime (min.) 3.6 min. (900w) half load runtime (min.) 11.9 min (450w) dc system voltage (vdc) 24 battery recharge rate (included batteries) less than 4.5 hours from 10% to 90% (typical, full load discharge) internal ups replacement battery cartridge see tripp lite rbc selector guide battery access front panel battery access door battery replacement description hot-swappable, user replaceable batteries voltage regulation voltage regulation description automatic voltage regulation (avr) maintains line power operation with an input voltage range of 182 to 278 overvoltage correction input voltages between 244 and 278 are reduced by 12% undervoltage correction input voltages between 182 and 206 are boosted by 12% user interface, alerts & controls front panel lcd display front panel lcd information and configuration screen offers detailed ups and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed lcd configuration and monitoring options) switches 3 pushbutton switches control off / on power status, mode selection and mute / enter control functions alarm cancel operation power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available audible alarm audible alarm indicates ups startup, power-failure, low-battery, overload, ups fault and remote shutdown conditions led indicators 5 leds indicate line power, battery power, overload, voltage regulation and battery low/replace status surge / noise suppression ups ac suppression joule rating 350 ups ac suppression response time instantaneous emi / rfi ac noise suppression yes physical included mounting accessory description 4 post rackmount installation accessories included installation form factors supported with optional accessories 2 post rackmount (2postrmkitwm); wallmount (2postrmkitwm); tower (2-9ustand); 2-4 post front rail rackmount (upshdearkit) primary form factor rackmount ups power module dimensions (hwd, in.) 3.5 x 17.5 x 13.5 3 / 5
ups power module dimensions (hwd, cm) 8.9 x 44.4 x 34.3 rack height (u spaces) 2 ups power module weight (lbs.) 34 ups power module weight (kg) 15.4 ups shipping dimensions (hwd / in.) 9 x 24 x 20.2 ups shipping dimensions (hwd / cm) 22.9 x 61 x 51.4 shipping weight (lbs.) 36 shipping weight (kg) 16.3 cooling method fan ups housing material steel environmental operating temperature range +32 to +104 degrees fahrenheit / 0 to +40 degrees celsius storage temperature range +5 to +122 degrees fahrenheit / -15 to +50 degrees celsius relative humidity 0 to 95%, non-condensing ac mode btu / hr. (full load) 100 ac mode efficiency rating (100% load) 97% communications communications interface db9 serial; epo (emergency power off); slot for snmp/web interface; usb (hid enabled) network monitoring port description supports detailed monitoring of ups and site power conditions poweralert software included communications cable usb and db9 cabling included watchdog compatibility supports watchdog application, os and hard-reboot restart options for remote applications line / battery transfer transfer time 2-4 milliseconds low voltage transfer to battery power (setpoint) 182 high voltage transfer to battery power (setpoint) 278 special features grounding lug back panel grounding lug cold start (startup in battery mode during a power failure) cold-start operation supported 4 / 5
high availability ups features hot swappable batteries green energy-saving features greater than 95% efficiency - green ups; individually controllable load banks certifications ups certifications ce; rohs (restriction of hazardous substances); tested to gost (russia) ups certification details iec 62040-1, iec 62040-2 class a emi warranty product warranty period (international) 2-year limited warranty product warranty period (mexico) 2-year limited warranty product warranty period (puerto rico) 2-year limited warranty ? 2015 tripp lite. all rights reserved. all trademarks are the sole property of their respective owners. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. photos may differ slightly from final products. 5 / 5


▲Up To Search▲   

 
Price & Availability of SMX1000RT2U

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X